Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int J Mol Sci ; 24(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: covidwho-2231230

RESUMEN

As new SARS-CoV-2 variants emerge, there is an urgent need to increase the efficiency and availability of viral genome sequencing, notably to detect the lineage in samples with a low viral load. SARS-CoV-2 genome next-generation sequencing (NGS) was performed retrospectively in a single center on 175 positive samples from individuals. An automated workflow used the Ion AmpliSeq SARS-CoV-2 Insight Research Assay on the Genexus Sequencer. All samples were collected in the metropolitan area of the city of Nice (France) over a period of 32 weeks (from 19 July 2021 to 11 February 2022). In total, 76% of cases were identified with a low viral load (Ct ≥ 32, and ≤200 copies/µL). The NGS analysis was successful in 91% of cases, among which 57% of cases harbored the Delta variant, and 34% the Omicron BA.1.1 variant. Only 9% of cases had unreadable sequences. There was no significant difference in the viral load in patients infected with the Omicron variant compared to the Delta variant (Ct values, p = 0.0507; copy number, p = 0.252). We show that the NGS analysis of the SARS-CoV-2 genome provides reliable detection of the Delta and Omicron SARS-CoV-2 variants in low viral load samples.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Estudios Retrospectivos , Carga Viral , Secuenciación de Nucleótidos de Alto Rendimiento
3.
Frontiers in medicine ; 8, 2021.
Artículo en Inglés | EuropePMC | ID: covidwho-1651966

RESUMEN

Introduction: Aside from the reverse transcription-PCR tests for the diagnosis of the COVID-19 in routine clinical care and population-scale screening, there is an urgent need to increase the number and the efficiency for full viral genome sequencing to detect the variants of SARS-CoV-2. SARS-CoV-2 variants assessment should be easily, rapidly, and routinely available in any academic hospital. Materials and Methods: SARS-CoV-2 full genome sequencing was performed retrospectively in a single laboratory (LPCE, Louis Pasteur Hospital, Nice, France) in 103 SARS-CoV-2 positive individuals. An automated workflow used the Ion Ampliseq SARS-CoV-2 panel on the Genexus Sequencer. The analyses were made from nasopharyngeal swab (NSP) (n = 64) and/or saliva (n = 39) samples. All samples were collected in the metropolitan area of the Nice city (France) from September 2020 to March 2021. Results: The mean turnaround time between RNA extraction and result reports was 30 h for each run of 15 samples. A strong correlation was noted for the results obtained between NSP and saliva paired samples, regardless of low viral load and high (>28) Ct values. After repeated sequencing runs, complete failure of obtaining a valid sequencing result was observed in 4% of samples. Besides the European strain (B.1.160), various variants were identified, including one variant of concern (B.1.1.7), and different variants under monitoring. Discussion: Our data highlight the current feasibility of developing the SARS-CoV-2 next-generation sequencing approach in a single hospital center. Moreover, these data showed that using the Ion Ampliseq SARS-CoV-2 Assay, the SARS-CoV-2 genome sequencing is rapid and efficient not only in NSP but also in saliva samples with a low viral load. The advantages and limitations of this setup are discussed.

4.
Microbiol Spectr ; 9(3): e0099621, 2021 12 22.
Artículo en Inglés | MEDLINE | ID: covidwho-1594122

RESUMEN

Due to increased demand for testing, as well as restricted supply chain resources, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection continues to face many hurdles. Pooling several samples has been proposed as an alternative approach to address these issues. We investigated the feasibility of pooling nasopharyngeal swab (NPS) or saliva samples for SARS-CoV-2 testing with a commercial assay (Idylla SARS-CoV-2 test; Biocartis). We evaluated the 10-pool and 20-pool approaches for 149 subjects, with 30 positive samples and 119 negative samples. The 10-pool approach had sensitivity of 78.95% (95% confidence interval [CI], 54.43% to 93.95%) and specificity of 100% (95% CI, 71.51% to 100%), whereas the 20-pool approach had sensitivity of 55.56% (95% CI, 21.20% to 86.30%) and specificity of 100% (95% CI, 25% to 100%). No significant difference was observed between the results obtained with pooled NPS and saliva samples. Given the rapidity, full automation, and practical advantages of the Idylla SARS-CoV-2 assay, pooling of 10 samples has the potential to significantly increase testing capacity for both NPS and saliva samples, with good sensitivity. IMPORTANCE To control outbreaks of coronavirus disease 2019 (COVID-19) and to avoid reagent shortages, testing strategies must be adapted and maintained for the foreseeable future. We analyzed the feasibility of pooling NPS and saliva samples for SARS-CoV-2 testing with the Idylla SARS-CoV-2 test, and we found that sensitivity was dependent on the pool size. The SARS-CoV-2 testing capacity with both NPS and saliva samples could be significantly expanded by pooling 10 samples; however, pooling 20 samples resulted in lower sensitivity.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virología , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Manejo de Especímenes/métodos , Adulto , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
ERJ Open Res ; 7(4)2021 Oct.
Artículo en Inglés | MEDLINE | ID: covidwho-1562071

RESUMEN

BACKGROUND: The current diagnostic standard for coronavirus disease 2019 (COVID-19) is reverse transcriptase-polymerase chain reaction (RT-PCR) testing with nasopharyngeal (NP) swabs. The invasiveness and need for trained personnel make the NP technique unsuited for repeated community-based mass screening. We developed a technique to collect saliva in a simple and easy way with the sponges that are usually used for tamponade of epistaxis. This study was carried out to validate the clinical performance of oral sponge (OS) sampling for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing. METHODS: Over a period of 22 weeks, we collected prospectively 409 paired NP and OS samples from consecutive subjects presenting to a public community-based free screening centre. Subjects were referred by their attending physician because of recent COVID-19 symptoms (n = 147) or by the contact tracing staff of the French public health insurance because they were considered as close contacts of a laboratory-confirmed COVID-19 case (n = 262). RESULTS: In symptomatic subjects, RT-PCR SARS-CoV-2 testing with OS showed a 96.5% (95% CI: 89.6-94.8) concordance with NP testing, and a 93.2% (95% CI: 89.1-97.3) sensitivity when using the IdyllaTM platform and a sensitivity of 76.3% (95% CI: 69.4-83.2) on the Synlab Barla laboratory platform. In close contacts the NP-OS concordance (93.8%, 95% CI: 90.9-96.7) and OS sensitivity (71.9%, 95% CI: 66.5-77.3) were slightly lower. CONCLUSION: These results strongly suggest that OS testing is a straightforward, low-cost and high-throughput sampling method that can be used for frequent RT-PCR testing of COVID-19 patients and mass screening of populations.

6.
PLoS One ; 16(4): e0243333, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1183614

RESUMEN

The emergence and quick spread of SARS-CoV-2 has pointed at a low capacity response for testing large populations in many countries, in line of material, technical and staff limitations. The traditional RT-qPCR diagnostic test remains the reference method and is by far the most widely used test. These assays are limited to a few probe sets, require large sample PCR reaction volumes, along with an expensive and time-consuming RNA extraction step. Here we describe a quantitative nanofluidic assay that overcomes some of these shortcomings, based on the BiomarkTM instrument from Fluidigm. This system offers the possibility of performing 4608 qPCR end-points in a single run, equivalent to 192 clinical samples combined with 12 pairs of primers/probe sets in duplicate, thus allowing the monitoring of SARS-CoV-2 including the detection of specific SARS-CoV-2 variants, as well as the detection other pathogens and/or host cellular responses (virus receptors, response markers, microRNAs). The 10 nL-range volume of BiomarkTM reactions is compatible with sensitive and reproducible reactions that can be easily and cost-effectively adapted to various RT-qPCR configurations and sets of primers/probe. Finally, we also evaluated the use of inactivating lysis buffers composed of various detergents in the presence or absence of proteinase K to assess the compatibility of these buffers with a direct reverse transcription enzymatic step and we propose several protocols, bypassing the need for RNA purification. We advocate that the combined utilization of an optimized processing buffer and a high-throughput real-time PCR device would contribute to improve the turn-around-time to deliver the test results to patients and increase the SARS-CoV-2 testing capacities.


Asunto(s)
COVID-19/diagnóstico , Técnicas Analíticas Microfluídicas/métodos , SARS-CoV-2/aislamiento & purificación , Manejo de Especímenes/métodos , Adulto , COVID-19/virología , Prueba de COVID-19/métodos , Cartilla de ADN , Pruebas Diagnósticas de Rutina/métodos , Femenino , Humanos , Masculino , MicroARNs/genética , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , SARS-CoV-2/genética , Sensibilidad y Especificidad
7.
Biopreserv Biobank ; 18(6): 517-524, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1125143

RESUMEN

In only a few months after its inception, the COVID-19 pandemic lead to the death of hundreds of thousands of patients and to the infection of millions of people on most continents, mostly in the United States and in Europe. During this crisis, it was demonstrated that a better understanding of the pathogenicity, virulence, and contagiousness of SARS-CoV-2, all of which were initially underestimated, was urgently needed. The development of diagnostic tests to identify SARS-CoV-2 or to detect anti-SARS-CoV2 antibodies in blood, of vaccines, and of preventive and curative treatments has been relying on intense activity of scientists in academia and industry. It is noteworthy that these scientists depend on the use of high-quality biological samples taken from positive COVID-19 patients in a manner that preserves their integrity. Given this unique and emergent situation, it was necessary to urgently establish biological collections clinically annotated for immediate development of clinical and translational research projects focusing on COVID-19 biological aspects. It is in this very specific context that biobanks must rapidly adapt their infrastructure and/or operational capacity to fulfill new critical needs. We report the establishment of a biobank dedicated to the collection of blood-derived products (plasma, serum, and leukocytes) from COVID-19 patients hospitalized in the Nice Pasteur Hospital (Nice, France).


Asunto(s)
Bancos de Muestras Biológicas , COVID-19/sangre , COVID-19/epidemiología , SARS-CoV-2/metabolismo , Investigación Biomédica Traslacional , Femenino , Francia , Humanos , Masculino
8.
Clin Pharmacol Ther ; 108(5): 1090-1097, 2020 11.
Artículo en Inglés | MEDLINE | ID: covidwho-615066

RESUMEN

Association between Hydroxychloroquine (HCQ) and Azithromycin (AZT) is under evaluation for patients with lower respiratory tract infection (LRTI) caused by the Severe Acute Respiratory Syndrome (SARS-CoV-2). Both drugs have a known torsadogenic potential, but sparse data are available concerning QT prolongation induced by this association. Our objective was to assess for COVID-19 LRTI variations of QT interval under HCQ/AZT in patients hospitalized, and to compare manual versus automated QT measurements. Before therapy initiation, a baseline 12 lead-ECG was electronically sent to our cardiology department for automated and manual QT analysis (Bazett and Fridericia's correction), repeated 2 days after initiation. According to our institutional protocol (Pasteur University Hospital), HCQ/AZT was initiated only if baseline QTc ≤ 480ms and potassium level> 4.0 mmol/L. From March 24th to April 20th 2020, 73 patients were included (mean age 62 ± 14 years, male 67%). Two patients out of 73 (2.7%) were not eligible for drug initiation (QTc ≥ 500 ms). Baseline average automated QTc was 415 ± 29 ms and lengthened to 438 ± 40 ms after 48 hours of combined therapy. The treatment had to be stopped because of significant QTc prolongation in two out of 71 patients (2.8%). No drug-induced life-threatening arrhythmia, nor death was observed. Automated QTc measurements revealed accurate in comparison with manual QTc measurements. In this specific population of inpatients with COVID-19 LRTI, HCQ/AZT could not be initiated or had to be interrupted in less than 6% of the cases.


Asunto(s)
Azitromicina , Infecciones por Coronavirus , Monitoreo de Drogas , Electrocardiografía/métodos , Hidroxicloroquina , Síndrome de QT Prolongado , Pandemias , Neumonía Viral/tratamiento farmacológico , Antiinfecciosos/administración & dosificación , Antiinfecciosos/efectos adversos , Antiinfecciosos/farmacocinética , Azitromicina/administración & dosificación , Azitromicina/efectos adversos , Azitromicina/farmacocinética , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/tratamiento farmacológico , Infecciones por Coronavirus/fisiopatología , Precisión de la Medición Dimensional , Monitoreo de Drogas/instrumentación , Monitoreo de Drogas/métodos , Monitoreo de Drogas/normas , Femenino , Humanos , Hidroxicloroquina/administración & dosificación , Hidroxicloroquina/efectos adversos , Hidroxicloroquina/farmacocinética , Síndrome de QT Prolongado/inducido químicamente , Síndrome de QT Prolongado/diagnóstico , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Neumonía Viral/diagnóstico , Neumonía Viral/fisiopatología , SARS-CoV-2 , Torsades de Pointes/inducido químicamente , Torsades de Pointes/prevención & control , Tratamiento Farmacológico de COVID-19
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA